Aims: The aim of the present study was to assess the clinical performance of a dual X-ray source multi-slice CT (MSCT) with high temporal resolution to assess the coronary status in patients with an intermediate pretest likelihood for significant coronary artery disease (CAD) without using negative chronotropic pretreatment.
Methods and results: Dual-source CT (DSCT) angiography (Siemens Definition) was performed in 90 patients with an intermediate likelihood for CAD who were referred for invasive coronary angiography. DSCT generated data sets with diagnostic image quality in 88 of the overall 90 patients. In six of seven patients with atrial fibrillation and in 46 of 48 patients with heart rates (HR) >65 b.p.m. image quality was diagnostic. In 20 of 21 patients with at least one stenosis >50% (sensitivity 95%) were correctly identified by DSCT-angiography. In 60 of 67 patients, a lesion >50% was correctly excluded (specificity 90%; positive predictive value 74%). The accuracy to detect patients with coronary stenoses >50% (sensitivity 92 vs. 100%; specificity 88 vs. 91%) was not significantly different among patients with HR >65 b.p.m. (n = 46) and <65 b.p.m. The concordance of DSCT-derived stenosis quantification showed good correlation (r = 0.76; P < 0.001) to quantitative coronary angiography with a slight trend to overestimate the stenosis degree.
Conclusion: DSCT is a non-invasive tool that allows to accurately rule out coronary stenoses in patients with an intermediate pretest likelihood for CAD, independent of the HR.
Key Words: Dual-source CT Computed tomography Coronary artery disease Multi-slice CT
Alexander W. Leber, Thorsten Johnson and Andreas Knez contributed equally to the study.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
G. Bastarrika, Y. S. Lee, W. Huda, B. Ruzsics, P. Costello, and U. J. Schoepf CT of Coronary Artery Disease Radiology, November 1, 2009; 253(2): 317 - 338. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Weustink, L. A. Neefjes, S. Kyrzopoulos, M. van Straten, R. Neoh Eu, W. B. Meijboom, C. A. van Mieghem, E. Capuano, M. L. Dijkshoorn, F. Cademartiri, et al. Impact of Heart Rate Frequency and Variability on Radiation Exposure, Image Quality, and Diagnostic Performance in Dual-Source Spiral CT Coronary Angiography Radiology, October 28, 2009; (2009) radiol.2533090358v1. [Abstract] [Full Text] |
||||
![]() |
T. Knickelbine, J. R. Lesser, T. S. Haas, E. R. Brandenburg, B. K. Gleason-Han, B. Flygenring, T. F. Longe, R. S. Schwartz, and B. J. Maron Identification of Unexpected Nonatherosclerotic Cardiovascular Disease With Coronary CT Angiography J. Am. Coll. Cardiol. Img., September 1, 2009; 2(9): 1085 - 1092. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Bastarrika, C. Thilo, G. F. Headden, P. L. Zwerner, P. Costello, and U. J. Schoepf Cardiac CT in the Assessment of Acute Chest Pain in the Emergency Department Am. J. Roentgenol., August 1, 2009; 193(2): 397 - 409. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Weustink, K. Nieman, F. Pugliese, N. R. Mollet, B. W. Meijboom, C. van Mieghem, G.-J. ten Kate, F. Cademartiri, G. P. Krestin, and P. J. de Feyter Diagnostic Accuracy of Computed Tomography Angiography in Patients After Bypass Grafting: Comparison With Invasive Coronary Angiography J. Am. Coll. Cardiol. Img., July 1, 2009; 2(7): 816 - 824. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Weustink, N. R. Mollet, L. A. Neefjes, M. van Straten, E. Neoh, S. Kyrzopoulos, B. W. Meijboom, C. van Mieghem, F. Cademartiri, P. J. de Feyter, et al. Preserved Diagnostic Performance of Dual-Source CT Coronary Angiography with Reduced Radiation Exposure and Cancer Risk Radiology, July 1, 2009; 252(1): 53 - 60. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Gibbons, P. A. Araoz, and E. E. Williamson The year in cardiac imaging. J. Am. Coll. Cardiol., January 6, 2009; 53(1): 54 - 70. [Full Text] [PDF] |
||||
![]() |
L. H. Piers, R. Dikkers, T. P. Willems, B. J.G.L. de Smet, M. Oudkerk, F. Zijlstra, and R. A. Tio Computed tomographic angiography or conventional coronary angiography in therapeutic decision-making Eur. Heart J., December 1, 2008; 29(23): 2902 - 2907. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. B. Meijer, Y. L. O, J. Geleijns, and L. J. M. Kroft Meta-Analysis of 40- and 64-MDCT Angiography for Assessing Coronary Artery Stenosis Am. J. Roentgenol., December 1, 2008; 191(6): 1667 - 1675. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-B. le Polain de Waroux, A.-C. Pouleur, C. Goffinet, A. Pasquet, J.-L. Vanoverschelde, and B. L. Gerber Combined coronary and late-enhanced multidetector-computed tomography for delineation of the etiology of left ventricular dysfunction: comparison with coronary angiography and contrast-enhanced cardiac magnetic resonance imaging Eur. Heart J., October 2, 2008; 29(20): 2544 - 2551. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Weustink, N. R. Mollet, F. Pugliese, W. B. Meijboom, K. Nieman, M. H. Heijenbrok-Kal, T. G. Flohr, L. A. E. Neefjes, F. Cademartiri, P. J. de Feyter, et al. Optimal Electrocardiographic Pulsing Windows and Heart Rate: Effect on Image Quality and Radiation Exposure at Dual-Source Coronary CT Angiography Radiology, September 1, 2008; 248(3): 792 - 798. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.-C. Pouleur, J.-B. le Polain de Waroux, J. Kefer, A. Pasquet, J.-L. Vanoverschelde, and B. L. Gerber Direct Comparison of Whole-Heart Navigator-Gated Magnetic Resonance Coronary Angiography and 40- and 64-Slice Multidetector Row Computed Tomography to Detect the Coronary Artery Stenosis in Patients Scheduled for Conventional Coronary Angiography Circ Cardiovasc Imaging, September 1, 2008; 1(2): 114 - 121. [Abstract] [Full Text] [PDF] |
||||
![]() |
H Scheffel, H Alkadhi, S Leschka, A Plass, L Desbiolles, I Guber, T Krauss, J Gruenenfelder, M Genoni, T F Luescher, et al. Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance Heart, September 1, 2008; 94(9): 1132 - 1137. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. B. Meijboom, C. A.G. Van Mieghem, N. van Pelt, A. Weustink, F. Pugliese, N. R. Mollet, E. Boersma, E. Regar, R. J. van Geuns, P. J. de Jaegere, et al. Comprehensive Assessment of Coronary Artery Stenoses: Computed Tomography Coronary Angiography Versus Conventional Coronary Angiography and Correlation With Fractional Flow Reserve in Patients With Stable Angina J. Am. Coll. Cardiol., August 19, 2008; 52(8): 636 - 643. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Bluemke, S. Achenbach, M. Budoff, T. C. Gerber, B. Gersh, L. D. Hillis, W. G. Hundley, W. J. Manning, B. F. Printz, M. Stuber, et al. Noninvasive Coronary Artery Imaging: Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young Circulation, July 29, 2008; 118(5): 586 - 606. [Full Text] [PDF] |
||||
![]() |
H. Klepzig Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease Eur. Heart J., March 1, 2008; 29(5): 680 - 680. [Full Text] [PDF] |
||||
![]() |
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al. Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology Eur. Heart J., February 2, 2008; 29(4): 531 - 556. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. J. Schoepf, P. Suranyi, C. Thilo, P. Costello, and P. L. Zwerner Replacing diagnostic catheterization with coronary CT angiography: the final frontier Eur. Heart J., October 1, 2007; 28(19): 2305 - 2306. [Full Text] [PDF] |
||||